Author ORCID Identifier
N/A
N/A
https://orcid.org/0000-0002-8604-6047
https://orcid.org/0000-0002-2006-885X
https://orcid.org/0000-0003-2760-531X
Document Type
Article
Publication Date
2013
College/Unit
School of Medicine
Department/Program/Center
Radiation Oncology
Abstract
Purpose: To evaluate conventional brachytherapy (BT) plans using dose-volume parameters and high resolution
(3 Tesla) MRI datasets, and to quantify dosimetric benefits and limitations when MRI-guided, conformal BT (MRIG-CBT) plans are generated.
Material and methods: Fifty-five clinical high-dose-rate BT plans from 14 cervical cancer patients were retrospectively studied. All conventional plans were created using MRI with titanium tandem-and-ovoid applicator (T&O) for delivery. For each conventional plan, a MRIG-CBT plan was retrospectively generated using hybrid inverse optimization. Three categories of high risk (HR)-CTV were considered based on volume: non-bulky (< 20 cc), low-bulky (> 20 cc and < 40 cc) and bulky (≥ 40 cc). Dose-volume metrics of D90 of HR-CTV and D2cc and D0.1cc of rectum, bladder, and sigmoid colon were analyzed.
Results: Tumor coverage (HR-CTV D90) of the conventional plans was considerably affected by the HR-CTV size. Sixteen percent of the plans covered HR-CTV D90 with the prescription dose within 5%. At least one OAR had D2cc values over the GEC-ESTRO recommended limits in 52.7% of the conventional plans. MRIG-CBT plans showed improved target coverage for HR-CTV D90 of 98 and 97% of the prescribed dose for non-bulky and low-bulky tumors, respectively. No MRIG-CBT plans surpassed the D2cc limits of any OAR. Only small improvements (D90 of 80%) were found for large targets (> 40 cc) when using T&O applicator approach.
Conclusions: MRIG-CBT plans displayed considerable improvement for tumor coverage and OAR sparing over conventional treatment. When the HR-CTV volume exceeded 40 cc, its improvements were diminished when using a conventional intracavitary applicator.
Digital Commons Citation
Anderson, James W.; Xia, Junyi; Flynn, Ryan T.; Modrick, Joseph M.; Bhatia, Sudershan K.; Jacobson, Geraldine M.; and Kim, Yusung, "High resolution (3 Tesla) MRI-guided conformal brachytherapy for cervical cancer: consequences of different high-risk CTV sizes" (2013). Faculty & Staff Scholarship. 2668.
https://researchrepository.wvu.edu/faculty_publications/2668
Source Citation
Anderson, J., Xia, J., Flynn, R., Modrick, J., Bhatia, S., & Jacobson, G. et al. (2013). Original paper
High resolution (3 Tesla) MRI-guided conformal brachytherapy for cervical cancer: consequences of different high-risk CTV sizes. Journal of Contemporary Brachytherapy, 5(2), 101-109. https://doi.org/10.5114/jcb.2013.36180
Comments
© 2013 Termedia Sp. z o. o. This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.