Abstract
Purpose
The aim of the present study was to compare the dose distribution generated from photon volumetric modulated arc therapy (VMAT), intensity modulated proton therapy (IMPT), and intensity modulated carbon ion therapy (IMCIT) in the delivery of hypo-fractionated thoracic radiotherapy.
Methods and materials
Ten selected patients who underwent thoracic particle therapy between 2015 and 2016 were re-planned to receive a relative biological effectiveness (RBE) weighted dose of 60 Gy (i.e., GyE) in 15 fractions delivered with VMAT, IMPT, or IMCIT with the same optimization criteria. Treatment plans were then compared.
Results
There were no significant differences in target volume dose coverage or dose conformity, except improved D95 was found with IMCIT compared with VMAT (p = 0.01), and IMCIT was significantly better than IMPT in all target volume dose parameters. Particle therapy led to more prominent lung sparing at low doses, and this result was most prominent with IMCIT (p < 0.05). Improved sparing of other thoracic organs at risk (OARs) was observed with particle therapy, and IMCIT further lowered the D1cc and D5cc for major blood vessels, as compared with IMPT (p = 0.01).
Conclusion
Although it was comparable to VMAT, IMCIT led to significantly better tumor target dose coverage and conformity than did IMPT. Particle therapy, compared with VMAT, improved thoracic OAR sparing. IMCIT, compared with IMPT, may further improve normal lung and major blood vessel sparing under limited respiratory motion.
Digital Commons Citation
Chi, Alexander; Lin, Lien-Chun; Wen, Sijin; Hsi, Wen-Chen; and Yan, Haijuan, "Comparison of photon volumetric modulated arc therapy, intensity-modulated proton therapy, and intensity-modulated carbon ion therapy for delivery of hypo-fractionated thoracic radiotherapy" (2017). Faculty & Staff Scholarship. 1489.
https://researchrepository.wvu.edu/faculty_publications/1489
Source Citation
Chi, A., Lin, L., Wen, S. et al. Comparison of photon volumetric modulated arc therapy, intensity-modulated proton therapy, and intensity-modulated carbon ion therapy for delivery of hypo-fractionated thoracic radiotherapy. Radiat Oncol 12, 132 (2017). https://doi.org/10.1186/s13014-017-0866-0
Comments
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.